Name
|
Description
|
Attributes
|
CommentLine1
|
An optional 60-byte free-text line for additional information related to the state vector contained in the EPV message. This field should contain all ASCII blanks when not used.
|
Type: String
Access: Read/Write
|
CommentLine2
|
An optional 60-byte free-text line for additional information related to the state vector contained in the EPV message. This field should contain all ASCII blanks when not used.
|
Type: String
Access: Read/Write
|
CommentLine3
|
An optional 60-byte free-text line for additional information related to the state vector contained in the EPV message. This field should contain all ASCII blanks when not used.
|
Type: String
Access: Read/Write
|
CoordinateSystem
|
This property is used to generate IIRV.
|
Type: Variable
Access: Read/Write
|
Counter
|
This property must be incremented for each vector in a set of vector data on a per-station per-transmission basis. This is not automatic and must be done manually within the Mission Sequence. This property is also referred to as the Sequence Number. This property is used to generate IIRV and EPV.
|
Type: Variable
Access: Read/Write
|
DataType
|
This property is used to generate IIRV and EPV.
|
Type: Variable
Access: Read/Write
|
DeclaredName
|
The name of the object as declared.
|
Type: String
Access: Read-Only
|
DestinationRouter
|
The destination routing indicator. Specifies the site from which the message was generated. If the message is for more than one station, this field should contain the word "MANY". This property is used to generate IIRV and EPV.
|
Type: String
Access: Read/Write
|
DisplayName
|
The name displayed for this object in output windows such as views, plots, and reports.
|
Type: String
Access: Read/Write
|
DragScaleFactor
|
The dimensionless drag scaling property, d. The effective drag coefficient is given by Cd(1+d). The implied decimal point is five places from the right. This value is displayed on Line 8 of the EPV report. This property is used to generate EPV.
|
Type: Variable
Access: Read/Write
|
ElementTypes
|
This property is used to generate EPV.
|
Type: Variable
Access: Read/Write
|
GeoMagIndex
|
The dimensionless geomagnetic activity index, Kp or Ap, at epoch. The implied decimal point is two places from the right. This value is displayed on Line 8 of the EPV report. This property is used to generate EPV.
|
Type: Variable
Access: Read/Write
|
GeoMagParm
|
The geomagnetic activity index type. This property is used to generate EPV.
|
Type: Variable
Access: Read/Write
|
Header
|
This property is not used.
|
Type: Variable
Access: Read/Write
|
LineTermination
|
This property is used to control what characters to add to the end of a line of a IIRV or EPV. In Windows, lines are terminated with a Carriage Return + Line Feed (CR+LF) Sequence, this is what tells editors like notepad.exe to start a new line for subsequent text. The standard AcqData format uses a (CR+CR+LF+LF) format.
|
Type: Variable
Access: Read/Write
|
MessageClass
|
This property is used to generate IIRV and EPV. For IIRV, this information is written into Line 1.
|
Type: Variable
Access: Read/Write
|
MessageID
|
A unique 7-character number (0000001 to 9999999) used to reference this message. This property is used to generate IIRV and EPV. For IIRV, this information is written into Line 1.
|
Type: Variable
Access: Read/Write
|
ObjectId
|
The unique identifier for the object.
|
Type: Variable
Access: Read-Only
|
ObjectType
|
The type of the object.
|
Type: String
Access: Read-Only
|
OriginatorCode
|
The originator identification. Alphabetic character that identifies the originator of message. This property is used to generate IIRV and EPV.
|
Type: String
Access: Read/Write
|
SatelliteIDCode
|
The Support Identification Code or Satellite ID Code. Also known as the SIC. Should be four numeric characters. This property is used to generate IIRV and EPV.
|
Type: Variable
Access: Read/Write
|
SolarFlux
|
Exospheric temperature, Tc, at epoch in units of degrees Kelvin with resolution to the nearest unit or of F10.7 solar flux at epoch in units of 10-22 W/m^2/Hz with resolution to the nearest tenth of a unit. The implied decimal place for the F10.7 solar flux is one place from the right. This field will contain all zeros when not used. This value is displayed on Line 8 of the EPV report. This property is used to generate EPV.
|
Type: Variable
Access: Read/Write
|
SolarParm
|
This value is displayed on Line 8 of the EPV report. This property is used to generate EPV.
|
Type: Variable
Access: Read/Write
|
SourceRouter
|
The originator router indicator. This property is used to generate IIRV and EPV.
|
Type: String
Access: Read/Write
|
VectorType
|
This property is used to generate IIRV and EPV.
|
Type: Variable
Access: Read/Write
|
VehicleIDCode
|
The Vehicle Identification Code. Should be two numeric characters (01-99). Defines the specific element of the SIC to be referenced. Example: for NASA Terra/AM, NASA Aqua/PM, and NASA Aura/CHEM, this field is filled with 01. This property is used to generate IIRV and EPV.
|
Type: Variable
Access: Read/Write
|